III. SANITARY CIRCUMSTANCES
The District Sanitary Inspectors served some 4,300
notices during the year, and in 60 cases legal proceedings
had to be employed to enforce compliance with them. These
figures are somewhat less than last year's, which is explained
partly by the fact that two Inspectors resigned
during the year, leaving the Borough 3 below the establishment
of 11 Inspectors.
Included in new legislation which came into effect
during the year were some provisions contained in the London
County Council (General Powers) Act, 1955, amonding existing
legislation and extending the powers of the Council under the
Public Health (London) Act, 1936, relating to stopped up and
defective drains, defective water supply, and nuisances
under the Fifth Schedule of the 1936 Act.
Atmospheric Pollution.
Towards the end of the year, two stations were set up
in the Borough for the daily measurement and recording of
atmospheric pollution.
The new stations measure the concentration of sulphur
dioxide and of smoke in the air by means of a combined smoke
filter and volumetric sulphur dioxide apparatus. Briefly,
air from outside a building is drawn at a steady rate, by
means of a small electric motor, through a filter paper, and
then through a bubbler containing dilute hydrogen peroxide,
which combines with the sulphur dioxide removed from the air
to form sulphuric acid. The volume of air is measured with
a gas meter. At the end of a day's run the concentration of
sulphur dioxide is calculated by formula and the concentration
of smoke is ascertained by comparing the stain on the
filter paper with a standard scale of shades.
These stations are sited at the Public Health Department
and at the Mile End Library, and are in addition to
the stations set up in 1953 at St.George's Town Hall and at
the London Jewish Hospital.
Instruments at the latter stations consist of deposit
gauges which collect grit, ash, etc., for the measurement of
deposited matter, and lead peroxide tubes for calculating
the activity of sulphur dioxide in the atmosphere. Monthly
readings continued to be taken at these stations during the
year, and the results, which will be found in Table 6 on
page 68 , were forwarded to the Department of Scientific
and Industrial Research.